Tankless Water Heater Error Code Guide
Diagnostic fault codes for Rinnai, Navien, Noritz, Rheem, and Bosch units from the TanklessFixer nationwide network.
Common Tankless Fault Codes & Remedies
When a fault occurs, your tankless wall controller flashes a numerical or alphanumeric code. Review common diagnostic codes below or contact our dispatch team for immediate technician assistance via our contact page or explore additional maintenance articles.
Rinnai Error Codes
- Code 10: Air intake or exhaust vent blockage. Check sidewall termination caps for debris.
- Code 11: No ignition. Verify gas supply valve is fully open and igniter electrode is clean.
- Code 12: Flame loss during burner operation. Indicates dirty flame sensor rod or low gas pressure.
- Code 25: Condensate drain line restriction. Clear blocked condensate trap.
Navien Error Codes
- Code E003: Ignition failure. Check gas manifold pressure and spark igniter gap.
- Code E012: Flame loss. Clean oxidized flame sensor or test gas pressure.
- Code E016: Heat exchanger overheating. Caused by heavy mineral scale accumulation; requires flushing.
Rheem Error Codes
- Code 11: Ignition failure. Check gas valve, igniter lead, and electrical grounding.
- Code 12: Flame failure. Inspect flame rod wire harness and gas supply lines.
- Code 29: Neutralizer / condensate blockage. Clear condensate trap hose.